Compare your costs
Have your installed quotes and utility bills ready. The heat pump vs. gas furnace cost calculator compares both paths using your inputs. Start with Quick comparison, review Step 2 assumptions, then read Results and Your break-even point. Change uncertain inputs to see whether the result stays stable or becomes financially close.
Cost crossover in years
The time when lower annual costs offset a higher upfront cost. Some assumptions produce no crossover. Compare that point with how long you expect to use the system.
Installed-cost menus show dated example ranges; these are starting points, not local quotes. Replace them with comparable written quotes and check whether they include installation, delivery, taxes, fees, and required extras. Choosing a price does not verify equipment performance or future costs.
Worked example buttons load editable inputs. Review every assumption before treating an example as your situation.
Review example inputs and sourced cost references
Try the calculator's worked examples
These use the same saved inputs as the calculator's example buttons. Load one, then change its assumptions.
Heat pump vs. gas furnace: compare your actual costs
Before comparing quotes, collect five inputs: (1) installed heat-pump cost, (2) installed furnace cost including any needed air-conditioning work, (3) electricity price per additional kWh, (4) gas price per additional therm, and (5) expected heating demand and seasonal efficiency. Use matching scopes and the same comparison period.
Quick operating-cost test: At $0.16/kWh electricity, $1.50/therm gas, and 95% furnace AFUE, a heat pump needs a seasonal COP above approximately 2.97 to cost less for heating energy alone. A lower energy bill does not necessarily offset a higher installation quote. Run the complete heat pump versus furnace cost calculator to compare both paths.
If you are replacing an aging system rather than choosing between fuel types, also see the HVAC repair vs. replace calculator.
A heat pump can have lower annual heating cost and also replaces air-conditioning equipment, but a gas furnace can still be cheaper where gas is inexpensive, electricity is expensive, or the heat-pump quote carries a large premium. Compare the systems using the same heating load and the same scope of work.
Compare your quotes →The mistake: comparing equipment labels instead of the whole decision
A heat pump is both a heater and an air conditioner. A gas furnace is a heater. If one quote includes a complete heat-pump system and the other includes only a furnace while your air conditioner also needs replacement, the sticker prices are not comparable.
Start by making the scopes equivalent. If the furnace path requires a new central air conditioner, coil, electrical work, venting, or other mandatory work, include it. Do the same for the heat-pump path.
What the calculator actually compares
The model uses your current gas-furnace fuel use to estimate the amount of useful heat your home needs in a typical year. Then it asks how much purchased energy a new furnace or a heat pump would need to deliver that same amount of heat.
EIA defines one therm as 100,000 Btu, and one kilowatt-hour of electricity as 3,412 Btu. DOE defines AFUE as the ratio of annual useful heat output to fuel input. Those conversions let both systems be compared against the same delivered heating load.
Why the heat-pump COP matters so much
A heat pump moves heat rather than creating it directly from resistance heat. ENERGY STAR says an air-source heat pump can deliver up to about three times as much heat energy as the electrical energy it consumes under favorable conditions. But the number that matters for your bill is not a marketing peak—it is a realistic seasonal COP for your climate, equipment, controls, ductwork, and backup-heat strategy.
Cold-weather performance has improved substantially. ENERGY STAR's current cold-climate criteria require qualifying ducted split systems to meet HSPF2 requirements and demonstrate a COP of at least 1.75 at 5°F, while retaining at least 70% of their 47°F heating capacity at 5°F. That does not mean every heat pump performs the same way in every house.
When is a heat pump cheaper to run than a gas furnace?
Compare the cost of delivering the same amount of heat. Under this model, the heat pump has a lower heating-energy bill when its seasonal COP is above this threshold:
Break-even seasonal COP = 29.3 × electricity price per kWh × new furnace AFUE ÷ gas price per therm. Enter AFUE as a fraction: 95% becomes 0.95.
For example, electricity at $0.16/kWh, gas at $1.50/therm, and a 95% AFUE furnace give a break-even seasonal COP of about 2.97. A heat pump averaging 2.8 COP has a higher heating-energy cost in that example. At 3.2 COP, it has a lower heating-energy cost.
This is an energy-cost threshold. It does not show whether energy savings repay a higher installed quote. The full calculator also compares upfront cost, incentives, maintenance, and the years you plan to use the system. It does not estimate cooling electricity or changes in fixed utility fees.
Which numbers should I take from my utility bills?
- Electricity: use the price of one additional kWh, including supply and delivery charges that vary with use. Leave out flat monthly fees that stay the same.
- Gas: use the charges that vary with each therm. Do not divide the entire bill by therms if it includes a fixed service fee. If your bill uses Ccf, use your utility's conversion to therms.
- Heating use: enter a full year's gas used for space heating. Exclude water heating and cooking; ask your utility for a heating-use estimate if your bill combines them.
- Efficiency: ask the installer for a seasonal estimate suited to your location, including expected backup heat. A single mild-weather COP rating is not a full-season estimate.
The calculator's What could change the result? section shows the energy-price threshold for your inputs. Change your rates and efficiency, then compare the full cost result as well.
Compare your quotes and utility rates →
Threshold calculation checked October 5, 2026. The model uses 100,000 ÷ 3,412 kWh per therm (about 29.3), based on EIA energy conversion factors. The threshold is derived from the equations shown below; it is not a prediction of your system's performance.
A simple worked example
Suppose a home currently uses 700 therms per year for space heating with an 80% AFUE furnace. Compare a 95% AFUE replacement furnace with a heat pump using a seasonal COP of 2.8. Assume electricity costs $0.16/kWh and gas costs $1.50/therm.
| Item | Heat pump | Gas furnace |
|---|---|---|
| Installed quote | $12,000 | $7,000 |
| Estimated annual heating energy | ≈ $938 | ≈ $884 |
| Example annual maintenance | $200 | $200 |
| 10-year cash cost | ≈ $23,380 | ≈ $17,840 |
In that example, gas wins on cost because its upfront quote is much lower and annual heating energy is slightly cheaper. But change the electricity rate, gas rate, heat-pump efficiency, incentives, or add a needed air-conditioner replacement to the furnace path and the result can move quickly.
The air-conditioner question can be decisive
If your furnace failed but your air conditioner is relatively new, replacing only the furnace can be a very different decision from replacing an aging furnace and aging air conditioner together. A heat pump already provides cooling, so a fair comparison should credit the furnace path with any AC work that is truly required.
ENERGY STAR specifically notes that when a home has a relatively new furnace and an older central AC, replacing the AC with a heat pump can create a dual-fuel system. That preserves the furnace as backup while adding heat-pump heating and new cooling.
Cold climate does not automatically rule out a heat pump
Modern cold-climate systems can provide meaningful heating output at low outdoor temperatures. Still, equipment selection and sizing matter. ENERGY STAR recommends having a contractor perform a Manual J heating and cooling load calculation and choosing equipment appropriate for the climate.
A cold-climate heat pump may be designed to carry the house without a furnace, or the home may use electric resistance or a gas furnace as backup. Backup strategy changes both comfort and operating cost, so it should be part of the quote—not an afterthought.
Do not count an expired federal credit
For 2026 installations, the federal Energy Efficient Home Improvement Credit under Section 25C is no longer available. The IRS says the credit is not allowed for property placed in service after December 31, 2025. State, local, utility, and manufacturer incentives may still exist, so enter only incentives you have verified.
What the calculator intentionally does not pretend to know
It does not forecast future utility inflation, assign a dollar value to emissions, model every hour of outdoor temperature, predict repair failures, or estimate home resale value. Those inputs can matter, but adding uncertain assumptions can make a calculator look more precise while making it less trustworthy.
The purpose is to expose the variables that can actually flip the decision and give you a checkable baseline.
A better decision process
Get comparable written quotes. Pull twelve months of utility usage. Separate space-heating gas from water-heating and cooking if possible. Ask for the exact furnace AFUE and heat-pump model. Ask how the contractor sized the system, what happens at low temperatures, and what backup heat is included.
Then change the calculator inputs. If the answer flips with a small change in utility rate or COP, you have a close call. If one option remains cheaper across a wide range of reasonable assumptions, the cost conclusion is more robust.
Heating example
Compare actual installed quotes using your electric and gas rates rather than a national-average savings claim.
Edge case worth testing
Test a cold-climate case with lower heat-pump performance and a high-electricity-rate case.
Run the decision with your numbers
The calculator shows upfront cost, annual heating cost, estimated crossover, and the electricity/gas price where operating-cost advantage flips.
Open the Heat Pump vs. Gas Furnace Calculator →What actually changes the answer?
Installed quotes, electricity and gas prices, seasonal heat-pump performance, furnace efficiency, required AC work, incentives, and the comparison horizon usually move the modeled result most.
What this model does not include
It does not predict hourly weather, exact backup-heat use, future utility-rate changes, comfort differences, duct performance, or contractor quality. Those can matter when the modeled costs are close.
Sources
- U.S. Energy Information Administration — Energy units and calculatorsAuthoritative reference
- U.S. Department of Energy — AFUE definition and heating equipment efficiencyGovernment / primary
- ENERGY STAR — Air-source heat pumpsGovernment / primary
- ENERGY STAR — Heat pump key product criteriaGovernment / primary
- ENERGY STAR — Clean heating and cooling / Manual J / dual fuelGovernment / primary
- Internal Revenue Service — 2025 Form 5695 instructions and termination of the Energy Efficient Home Improvement CreditGovernment / primary
Utility prices, incentives, and contractor quotes change. Verify local numbers before making a purchase decision.